LDS-S50 leak test system with integrated helium recovery.
HELIUM LEAK TEST FOR FUEL COMPONENT
LDS-S50 leak test system with integrated helium recovery.
LARGE VOLUME TEST ITEMS
DIFFERENT TANK VARIANTS
NOISE PROTECTION
AUTOMATIC ADAPTATION
TECHNICAL DATA
Helium leak testing with double chamber system
Total capacity
up to 1500 L
Test pieces per chamber
1 piece
System capacity
up to 120 pcs./h
Limit leakage rate
typically 1.0 E-5 mbar l/s
Test gas pressure
typically 2 bar
PRODUCT DESCRIPTION
The LDS-S50 leak test system is suitable for the testing components of different applications. The unit has a two-chamber system for SCR tanks and integrated helium recovery. We achieve short inspection times through optimised inspection process.