LDSeco
Leak detection system with changeable chambers
Double chamber, ergonomic layout
Climatic components, SCR components, pressure accumulator, valve blocks

The most important characteristics are:
Fully automatic test cycle according to recipe presets without operator influence Test part specific changeable chambers, automatic chamber detection and recipe assignment Tooling time for changeable chambers less than 5 min Chamber outline individual manufactured according to customer specification and test part shape, therefor future-proof and extendable 1 test part per chamber Field-tested standard system with useful equipment Quality management because of certified calibration and process monitoring Pre- and post- workplaces are possible

  • Ergonomic chamber arrangement
  • Chamber according to customer specification
  • Testing test parts of different applications
  • Short cycle times because of optimized process
  • Pumping unit with high pumping speed
  • Highest flexibility because of standardized modular design
  • Numerous optional accessories (Scanner, Printer, Marker, Data management, pre- and post- workplaces, …)
Double chamber system
Test parts per chamber 1 piece
System capacity 100 pic / h
Min. leak rate typic 9,0 x 10-6 mbar l / s
Test pressure typic 40 bar Helium
Chamber size test part specific
LDSergo

Leak detection system
Double chamber, ergonomic layout
Climatic and fuel components

The most important characteristics are:
Fully automatic test cycle according to recipe presets without operator influence Test part specific work piece carrier, automatic work piece carrier detection and recipe assignment Tooling time for work piece carrier less than 2 min Chamber for a flexible test part arrangement and variable test part shapes, therefor future-proof and extendable Variable amount of test parts per chamber (1-4 pcs.) Single test and leak rate verification possible Field-tested standard system with useful equipment Quality management because of certified calibration and process monitoring

  • Ergonomic chamber layout
  • Available as single or double chamber system
  • Chamber size according to customer needs
  • For testing parts of variable applications
  • Short cycle times because of optimized process
  • Pumping unit with high pumping speed
  • Highest flexibility because of standardized modular design
  • Numerous optional accessories (Scanner, Printer, Marker, Data management, …)
Double chamber system
(single chamber system as option)
Test parts per chamber 4 pieces
System capacity 320 pic / h
Min. leak rate typic 1,0 x 10-5 mbar l / s
Test pressure typic 40 bar Helium
Chamber size 250l – 850l
LDSclima
Leak detection system
Double chamber, ergonomic layout
Climatic components

The most important characteristics are:
Fully automatic test cycle according to recipe presets without operator influence Test part specific work piece carrier, automatic work piece carrier detection and recipe assignment Tooling time for work piece carrier less than 2 min Chamber for a flexible test part arrangement and variable test part shapes, therefor future-proof and extendable Variable amount of test parts per chamber (1-4 pcs.) Single test and leak rate verification possible Field-tested standard system with useful equipment Quality management because of certified calibration and process monitoring

  • Ergonomic chamber layout
  • Chamber size according to customer needs
  • For testing parts of variable applications
  • Short cycle times because of optimized process
  • Pumping unit with high pumping speed
  • Highest flexibility because of standardized modular design
  • Numerous optional accessories (Scanner, Printer, Marker, Data management, …)
Double chamber system
Test parts per chamber 4 pieces
System capacity 320 pic / h
Min. leak rate typic 1,0 x 10-5 mbar l / s
Test pressure typic 40 bar Helium
Chamber size 250l – 850l